TnT® Coupled Reticulocyte Lysate System Technical Bulletin

Instructions for Use of Product(s)
L4610, L4600, L4950, L5010, L5020, L4601, L4611

Literature # TB126

The TnT® Coupled Reticulocyte Lysate Systems offer researchers an alternative for eukaryotic in vitro translations: a single tube, coupled transcription/translation system. The TnT® Lysate Systems greatly simplify the process and reduce the time required to obtain in vitro translation results. Standard rabbit reticulocyte lysate translations commonly use RNA synthesized in vitro from SP6, T3 or T7 RNA polymerase promoters and require three separate reactions with several steps between each reaction. The TnT® Systems bypass many of these steps by incorporating transcription directly in the translation mix.

In most cases, the TnT® Lysate reactions produce significantly more protein (two- to sixfold) in a 1.5-hour reaction than standard in vitro rabbit reticulocyte lysate translations using RNA templates. In comparisons of 35S incorporation, the TnT® Lysate reactions incorporate significantly more radiolabel than do standard in vitro translation reactions.

Summary of Changes
The following changes were made to the 8/25 revision of this document:
1. Removed expired Cat.# Y4041, Canine Pancreatic Membranes and Section 6 protocol.
2. Updated the cover image and fonts.
3. Removed other discontinued products from Section 10.C. Related Products.
4. Renumbered references after removal those in the deleted Section 6 protocol for microsomal membranes.

Revised 8/25.

Experienced User Protocols